Výsledky hledání

sektor: zdravotnictví v celém archivu

zrušit filtry CZ · EN/orig

13 karet z 13 položek

2

17th August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 17th August, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Colombia’s Ministry of Justice has experienced a ransomware attack that affected part of its technology infrastructure and disrupted public services related to illicit-drug monitoring and legal processes. Officials confirmed that some files were encrypted but stated that no data theft was detected during the incident. MyDr, Poland’s primary…

KEV ✓ EPSS 0.00 CVSS 9.8 CVE-2026-53413 CVE-2026-65400 CVE-2026-68820 CVE-2026-71362 Microsoft Apple Adobe Zoom veřejná správa zdravotnictví obrana energetika IL

Check Point Research ·

2

Flow Neuroscience FL-100

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 are affected: Flow Neuroscience FL-100 Halo Neuroscience FL-100 CVSS Vendor Equipment Vulnerabilities v3 8.1 Flow Neuroscience Flow Neuroscience FL-100 Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Healthcare and Public Health Countries…

EPSS 0.00 CVSS 8.1 CVE-2026-18164 Flow Neuroscience zdravotnictví US

CISA Advisories ·

Siemens Desigo DXR and PXC Controllers

View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 …

EPSS 0.00 CVSS 4.3 CVE-2026-59693 Siemens energetika zdravotnictví výroba a průmysl doprava US

CISA Advisories ·

2

Pulsetto Vagus Nerve Stimulator

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to use hidden commands to disable electrical safety mechanisms or modify other stimulation output settings. The following versions of Pulsetto Vagus Nerve Stimulator are affected: Pulsetto Vagus Nerve Stimulator vers:all/* (CVE-2026-18844) CVSS Vendor Equipment Vulnerabilities v3 8.1 Pulsetto Pulsetto Vagus Nerve Stimulator Hidden Functionality Background Critical Infrastructure Sectors: Healthcare and…

EPSS 0.00 CVSS 8.1 CVE-2026-18844 Pulsetto zdravotnictví US

CISA Advisories ·

Mira Hormone Monitor, Mira Android App

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access unauthorized health profile information, make changes to health information, cause a denial-of-service condition, disclose session token information, and obtain control of user accounts. The following versions of Mira Hormone Monitor, Mira Android App are affected: Mira Monitor Firmware 1.7.1.47 (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE…

EPSS 0.00 CVSS 9.8 CVE-2026-64934 CVE-2026-66098 CVE-2026-66340 CVE-2026-66832 CVE-2026-66875 CVE-2026-67558 CVE-2026-67568 CVE-2026-68067 Quanovate Tech Inc. zdravotnictví US

CISA Advisories ·

1

#StopRansomware: Gunra Ransomware

Advisory at a Glance Title #StopRansomware: Gunra Ransomware Original Publication August 10, 2026 Executive Summary Gunra is a ransomware-as-a-service (RaaS) used by affiliates to target government, critical infrastructure, and other organizations. The Gunra ransomware variant first appeared in 2025 and expanded to RaaS operations in 2026. The actors leverage a double-extortion model, both encrypting data and threatening to publish exfiltrated data to a dedicated leak site (DLS) if the ransom…

KEV ✓ EPSS 0.98 CVE-2024-55591 CVE-2025-24472 veřejná správa zdravotnictví finance energetika US

CISA Advisories ·

2

Medixant RadiAnt DICOM

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause the application to crash if a maliciously crafted DICOM file is opened. The following versions of Medixant RadiAnt DICOM are affected: RadiAnt DICOM <=2025.2 CVSS Vendor Equipment Vulnerabilities v3 4.3 Medixant Medixant RadiAnt DICOM Out-of-bounds Write Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Poland…

EPSS 0.00 CVSS 4.3 CVE-2026-17264 Medixant zdravotnictví US

CISA Advisories ·

ABB Ability Zenon

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to bypass security, crash systems, execute unauthorized actions, or compromise data. The following versions of ABB Ability Zenon are affected: IIoT services with MongoDB (4.2) installed on ABB Ability Zenon vers:all/* CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Zenon Improper Handling of Length Parameter Inconsistency, Improper Neutralization of Null Byte or NUL Character, Collapse of Data…

KEV ✓ EPSS 0.83 CVSS 7.8 CVE-2020-7921 CVE-2020-7928 CVE-2025-14847 ABB energetika zdravotnictví vodárenství výroba a průmysl US

CISA Advisories ·

1

Thermo Fisher Applied Biosystems Genetic Analyzers

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to modify .fsa/.hid output files, tampering with DNA data and resulting in inaccurate test results. The following versions of Thermo Fisher Applied Biosystems Genetic Analyzers are affected: Applied Biosystems 3500/3500xL Series Data Collection Software <=4.0.2 Applied Biosystems 3730/3730xL Series Data Collection Software <=5.0.2 Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software <=1.2.5…

EPSS 0.00 CVSS 8.4 CVE-2026-17583 Thermo Fisher zdravotnictví US

CISA Advisories ·

1

3rd August – Threat Intelligence Report

For the latest discoveries in cyber research for the week of 27th July, please download our Threat Intelligence Bulletin. TOP ATTACKS AND BREACHES Minnesota IT Services has confirmed coordinated cyberattacks affecting more than 30 community water utilities across the state. The incidents briefly disrupted a treatment plant in Braham and affected industrial control systems. Officials reported that drinking water safety was not affected. While the attack was not officially attributed, federal…

KEV ✓ EPSS 0.70 CVSS 9.8 CVE-2026-20316 CVE-2026-42897 CVE-2026-59309 CVE-2026-59310 CVE-2026-59726 CVE-2026-63077 CVE-2026-66066 Check Point Cisco Broadcom Microsoft vodárenství finance zdravotnictví telekomunikace IL

Check Point Research ·

2

You were onto something with “It’s the Climb,” Miley

Welcome to this week’s edition of the Threat Source newsletter. For my fianceé’s 30th birthday, I took her on a weekend trip to Shenandoah National Park – a favorite of ours since we went to a wedding there several years back. We’ve done several incredible hikes over the years, but one in particular had always loomed over my head: Old Rag, a 9.3 mile circuit hike that’s largely considered the most difficult in Virginia. I've always been warned that at the beginning and end, you hate Old Rag.…

Cisco Microsoft Check Point Zoho zdravotnictví veřejná správa vodárenství US

Cisco Talos ·

OctLurk and SilkLurk: newly identified tailored backdoors in cyber-espionage campaign in Central Asia

Introduction We have been tracking two new backdoors, OctLurk and SilkLurk, observed in attacks against government organizations primarily in Central Asia since January 2025. Identified victims are located in Afghanistan, Kyrgyzstan, Tajikistan, Uzbekistan, Kazakhstan, and the Syrian Arab Republic. These organizations operate across several sectors, including healthcare, research, government offices, ministries of foreign affairs, logistics, law‑enforcement agencies, urban planning and…

veřejná správa zdravotnictví školství RU

Securelist (Kaspersky) ·